Region

Applications

Carcinogenic amines on Kinetex 2.6 µm EVO C18

Application Detail (App ID: 23042)

Part No:00F-4725-AN
Dimensions:150 x 2.1 mm ID
Elution Type:Gradient
Elution A:10 mM ammonium acetate/ ACN (95:5)
Elution B:Acetonitrile
Gradient Profile:
Step No. Time (min) Pct A Pct B
1 0 95 5
2 10 5 95

Flow Rate:0.4 mL/min
Col. Temp: 50 °C
Detection: UV-Vis Abs.-Variable Wave.(UV) @ 240 nm (22°C)
Note:Forced degradation protocol:
Reconstitute 1 mg of cefaclor neat standard with 1.0 mL of 1 M HCl. Heat the solution at 60 ºC for 6 hours then neutralize with 1.0 mL of 1 M NaOH. Refrigerate until ready to inject.

Analyte Details

Analyte Detail not available

1
4-Methyl-m-phenylenediamine
search

2
o-Anisidine
search

3
o-Toluidine
search

4
Benzidine
search

5
4-Chloroaniline
search

6
3,3'-Dimethoxybenzidine
search

7
3,3'-Dimethylbenzidine
search

8
2-Naphthylamine
search

9
2,4,5-Trimethylaniline
search

10
4,4'-methylenedio-toluidine
search

11
4-Aminobiphenyl
search

12
3,3'-Dichlorobenzidine
search

13
2,2'-Dichloro-4,4'-methylenedianiline
search

14
o-Aminoazotoluene
search